Excellent NS0-593 Study Guide To Help You Prepare For Network Appliance NS0-593 Exam

Excellent NS0-593 Study Guide To Help You Prepare For Network Appliance NS0-593 Exam

Do you know the requirements for earning the NetApp Certified Support Engineer – ONTAP Specialist certification? First, you need to pass the NS0-194 exam to earn the NetApp Certified Support Engineer certification as the prerequisite. Then pass the NS0-593 exam successfully. To all, the excellent NS0-593 study guide is available online to help you pass your Network Appliance NS0-593 exam successfully. A good method to get ready for the actual NetApp NS0-593 exam is to choose the Network Appliance NS0-593 study guide of ITExamShop to practice all those questions and answers.

Check Network Appliance NS0-593 Free Demo Questions First

Page 1 of 1

1. The motherboard of Node-01 is being replaced. To perform this task, a takeover was Initiated from Node-02. Node-02 panics showing the string below.

PANIC; Permanent errors on all HA mailbox disks (while marshalling header) in SKprocess fnmbx_instanceWorker on release 9.5P8 (C)

What has happened in this situation?

2. You receive the "Unable to connect to the management gateway server"error when trying to connect to a node management IP.

In this situation, how do you determine whether core dumps are generated for the mgwd user space process?

3. A system panic due to an "L2 watchdog timeout hard reset" error occurred. You have found a FIFO message in the SP log.

Which FIFO message Is useful for Investigating this Issue?

4. Your customer has deployed a two petabyte NetAppONTAP FlexGroup volume across their 4-node ONIAP 9.8 cluster. They plan to store over three billion files. They want to prevent file 10 conflicts since files are placed into the FlexGroup volume.

In this scenario, which two NFS SVM parameters should be enabled? (Choose two.)

5. A customer's storage administrator Informs you about the deactivated Automatic Switchover (AUSO) feature on their MetroCluster IP environment.

What Information would you tell your customer in this scenario?

6. Referring to the exhibit, what do you need to do to return the MetroCluster to a normal state?



7. 1.After expanding a two-node AFF A300 cluster with two AFF A700 nodes, you observe latencies when data is accessed indirectly. The system node run -node -command netstat command shows retransmits and packet drops on the LIFs. The AFF A700 nodes with 40 Gbps and the AFF A300 connect with 10 Gbps to the cluster interconnect. You are using Cisco Nexus 3132Q cluster interconnect switches. You just updated to ONTAP 9.8 software.

In this scenario, what is causing this problem?