Real Exam Questions For NetApp Certified Support Engineer – ONTAP Specialist NS0-592 Exam

Real Exam Questions For NetApp Certified Support Engineer – ONTAP Specialist NS0-592 Exam

Real exam questions have been collected by ITExamShop for NetApp Certified Support Engineer – ONTAP Specialist NS0-592 exam. When come to NetApp Certified Support Engineer – ONTAP Specialist certification, you need to pass NS0-194 exam to be a NetApp NCSE certified, then come to pass Network Appliance NS0-592 exam successfully. Real NS0-592 exam questions are based on the actual exam objective, so we are so confident that NS0-592 real questions are valid for real NetApp Certified Support Engineer – ONTAP Specialist NS0-592 exam.

You can fist come here to read NetApp NCSE ONTAP Specialist NS0-592 Free Questions First

Page 1 of 2

1. A customer has created an interface group (igroup) named a0a, a VLAN named a0a-2500, and a data LIF associated with the VLAN interface that has been assigned an IP of 10.254.10.100. The customer is able to ping 10.254.10.100 from a Windows client without any issues, but data traffic is not working.

In this scenario, what is the solution to the problem?

2. You migrated from a FAS3250 system to a new A200 system. After the migration, you notice that data compaction fails to be enabled on the migrated volumes.

In this scenario, which statement is correct?

3. Click the exhibit button.





A customer has an FC SAN with brocade switches. Each server attached to the SAN gas four FC ports. The customer describes that one of their servers has only four paths to the LUNs configured on the cluster. There should be eight paths on all the other servers. The switch administrator has verified the zone configuration.

Referring to the exhibit, which two actions would you perform to troubleshoot the problem? (Choose two.)

4. Click the exhibit button.





When you log in to a node, a warning is displayed as shown in the exhibit.

Which statement is correct in this scenario?

5. You are running a fabric-attached MetroCluster configuration with ONTAP 9.5software. There is a maintenance window for the upcoming weekend. Plexes in your mirrored aggregates between your two data centers have not been synchronizing for two days.

When the resynchronizations begin, they are not as quick as expected, and the process takes more than a day.

You have been modifying the number of concurrent I/O streams using the storage raid-options modify raid. resync.num_concurrent_ios_per_rg command, but the resynchronization speed stays slow.

You have four separate ISLs between your data centers using Brocade 6510 switches.

Hardware problems are not an issue.

Which two actions should you take to prevent this problem in the future? (Choose two.)

6. Click the exhibit button.





Your customer is calling about their MetroCluster environment. They have provided you with the output of the metrocluster interconnect adapter show command.

Referring to the exhibit, which statement is correct?

7. Click the exhibit button.





The storage administrator for the company example.com is attempting to join an SVM to their Active Directory as SVM1. The computer account must also be joined to the Secure organizational unit. Attempts to perform this action using the CLI fail with the error message shown in the exhibit.

What is the reason for this error?

8. A reboot was performed by a watchdog reset on the node.

In this scenario, which statement is true?

9. In a 4-node MetroCluster cluster, both clusters are alerting that the connection to an ATTO bridge is lost.

Which three components should be verified to determine what is causing this problem? (Choose three.)

10. Your customer has initiated several volume move commands to redistribute the workload in their 8-node cluster. To verify that this process is not affecting their client access, they were monitoring the network switches that provide client access, but they do not see the network load of the volume move command.

In this scenario, what is the reason for the behavior?